<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15400</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: Drum Vacuum turned off unexpectingly.
Resume to continue
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800_Proofing</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<OperatorAction>
<DescriptionText><text>
Click RESUME to continue.
Write down the time of the error and report to Creo.
</text></DescriptionText>
</OperatorAction>
<ServiceInformation>
<DescriptionText><text>
Obtain the workstation log file around the time of the error as well as the nvs dump file.
Report to the Spectrum firmware engineer.
</text></DescriptionText>
</ServiceInformation>
<Cause>
The drum vacuum pump has been turn off unexpectedly before or during media unload.
May be caused by faulty TEE board or dvac pump.
</Cause>
<SeeAlso>